Application examples for external inputs of the Smart programmable timer premium
The Smart programmable timer premium has two configurable inputs E1 and E2 (230 V / 50 Hz) for connecting external signal transmitters (e.g. blind switches / environmental sensors etc.).
The following configurations are possible:
[ 0 ] Off
[ 1 ] UP (shutter mode)
[ 2 ] DOWN (shutter mode)
[ 3 ] UP (shutter mode)
[ 4 ] DOWN (shutter mode)
[ 5 ] UP / Stop / Down
[ 6 ] Switch automatic mode on/off (normally open contact, NO)
[ 7 ] Switch automatic mode on/off (normally closed contact, NC)
[ 8 ] External wind signal, NO
[ 9 ] External rain signal, NO
NOTE
If manual mode is active, the inputs are not taken into account (The wind function
excluded).
Both inputs are configured independently of each other.
By factory default, both external inputs are set to 0. Accordingly, the external
pushbuttons have no function.
Application 1:
Control for tube motors:
Select under menu item 9-8-6
for input 1 = 1 UP
for input 2 = 2 DOWN
Blind pushbuttons (recommended) or switches can be used for control. When the
button is pressed briefly, the Smart programmable timer premium switches to self-holding and moves the shutter completely UP or DOWN. A further pushbutton command during the movement stops the motor.
Application 2:
Control for external venetian blinds:
Select under menu item 9-8-6
for input 1 = 3 UP (blind mode)
for input 2 = 4 DOWN (blind mode)
Blind pushbuttons (recommended) or switches can be used for control. When the
button is pressed briefly, the Smart programmable timer premium switches to self-holding and moves the shutter completely UP or DOWN. A further pushbutton command during the movement stops the motor.
Application 3:
UP / Stop / Down:
Select under the menu item 9-8-6
for input 1 or 2 = 5 UP / Stop / Down
With this application you can operate the roller shutter with a single-pole pushbutton. The
switching sequence is UP / Stop / Down / Stop / Up /....
In this function, the motor cannot be moved specifically in one direction, but uses the counter command in
its own logic.
Application 4:
Automatic Manual Switching:
Select under the menu item 9-8-6
for input 1 or 2 = 6 or 7 (depending on which type of contact you use)
Switch automatic mode on/off
You can deactivate the automatic function of the Smart programmable timer premium, for example, to prevent the roller shutter from closing when the window is open. You can also deactivate the automatic function of all connected timers via a central switch, so that the shutters do not close automatically if you wish, for example if you have visitors and do not want to sit behind lowered shutters all at once.
Application 5:
Wind detection:
Select under the menu item 9-8-6
for input 1 or 2 = 8 wind
If 230V is switched to the selected input of the Smart programmable timer premium by an external wind sensor and its evaluation electronics
input of the Smart programmable timer premium, this is interpreted by the timer as wind and the timer moves the motor in the preset direction and locks the manual and automatic operation until the 230V signal is switched off.
Application 6:
Rain detection:
Select under the menu item 9-8-6
for input 1 or 2 =9 Rain
In addition, switch menu item 8 to ON and define the desired direction of travel.
If an external rain sensor and its evaluation electronics switch 230V to the selected input of the Smart
If 230V is switched to the selected input of the Smart programmable timer premium by an external rain sensor and its evaluation electronics, this is interpreted as rain by the timer and the timer moves the motor in the set direction and locks the automatic operation until the 230V signal is switched off. Manual operation is possible when rain is active.